Loading...
  • Condensing Units and Packaged Systems
  • Air-Cooled Condensing Units
  • 4 HP - 13 HP Horizontal Air Discharge

climate-control Model : CBT0751M6D   legacy

List Price: US$ 34,852
R-404A/507
Outdoor Application Capacity 76,660
AWEF N/A
Meets Minimum AWEF

General
Product Brand Climate Control
Product Type Air-Cooled Condensing Units
Product Category Condensing Units and Packaged Systems
Product Style 4 HP - 13 HP Horizontal Air Discharge
Product Classification legacy
Application Outdoor
Operating Range Medium Temperature
Compressor Type Bitzer
Compressor P N 4DES-7
Voltage 460/3/60
Cabinet 2 Fan
Refrigerant Type R-404A/507
Performance
Ambient Temperature F 95°F
Suction Temperature F 25°F
Capacity BTUH 76,660
Refrigerant R-404A/507
Physical
Height (In.) 39 1/4
Depth In 36 3/4
Width (In.) 63 3/4
Approx Net Weight (lbs) 862
Electrical Ratings
Compressor Model Number 4DES-7
Power 460/3/60
Compressor RLA 15.3
Compressor LRA 88
Fan Motor Qty 2
Fan Motor Fla 3.8
MCA 22.9
MOPD 35
Connections
Liquid Od 5/8
Suction Od 1.125

{option_description=Dual pressure control with adjustable high & low pressure settings, notes=Standard heated and insulated receiver kit option can't be used with this option. Contact factory, option_type=Electrical, models_used_on=All, option_code=SW.002} {option_description=Adjustable high pressure switch w/ manual reset & adjustable low pressure switch, notes=null, option_type=Electrical, models_used_on=All, option_code=SW.007} {option_description=Compressor Fusing, notes=null, option_type=Electrical, models_used_on=2 Fan Large, option_code=CFS.001} {option_description=Defrost Timer - Air, notes=Medium temperature applications only., option_type=Electrical, models_used_on=All M6, option_code=DFT.001} {option_description=Fan Cycling - Temperature & Pressure, notes=null, option_type=Electrical, models_used_on=2 Fan, option_code=FCY.014} {option_description=Phase Loss Monitor, notes=null, option_type=Electrical, models_used_on=All, option_code=PLM.001} {option_description=Variable Speed EC Motor with Orbus Controller, notes=null, option_type=Electrical, models_used_on=1 Fan (208-230/3/60), option_code=MS.001-1} {option_description=Variable Speed EC Motor with Orbus Controller, notes=Not suitable for 2 Fan Large (230V) Units , option_type=Electrical, models_used_on=2 Fan (208-230/3/60), option_code=MS.001-2} {option_description=Variable Speed EC Motor with Orbus Controller, notes=Not suitable for 2 Fan Large (230V) Units (901M6 - 1001M6 1201L6 - 1301L6), option_type=Electrical, models_used_on=2 Fan (208-230/3/60), option_code=MS.001-2} {option_description=Variable Speed EC Motor with Orbus Controller, notes=null, option_type=Electrical, models_used_on=2 Fan Large (230V), option_code=MS.001-3} {option_description=Variable Speed EC Motor with Orbus Controller, notes=null, option_type=Electrical, models_used_on=1 Fan (460V), option_code=MS.001-4} {option_description=Variable Speed EC Motor with Orbus Controller, notes=Not suitable for 2 Fan Large (460V) Units (901M6 - 1001M6 1201L6 – 1301L6), option_type=Electrical, models_used_on=2 Fan (460V), option_code=MS.001-5} {option_description=Variable Speed EC Motor with Orbus Controller, notes=Not suitable for 2 Fan Large (460V) Units , option_type=Electrical, models_used_on=2 Fan (460V), option_code=MS.001-5} {option_description=Variable Speed EC Motor with Orbus Controller, notes=null, option_type=Electrical, models_used_on=2 Fan Large (460V), option_code=MS.001-6} {option_description=Circuit Breakers (Compressor Control & Fan), notes=null, option_type=Electrical, models_used_on=2 Fan Large - 230V, option_code=ELC.007-1} {option_description=Circuit Breakers (Compressor Control & Fan), notes=null, option_type=Electrical, models_used_on=2 Fan Large - 460V, option_code=ELC.007-2} {option_description=NEMA Contactors, notes=null, option_type=Electrical, models_used_on=2 Fan Large - 460V, option_code=ELC.008-1} {option_description=NEMA Contactors, notes=null, option_type=Electrical, models_used_on=2 Fan Large - 230V, option_code=ELC.008-2} {option_description=Fan Cycling - Temperature & Pressure, notes=null, option_type=Electrical, models_used_on=1 Fan, option_code=FCY.002-1} {option_description=Fan Cycling - Temperature & Pressure, notes=null, option_type=Electrical, models_used_on=2 Fan Large, option_code=FCY.002-2} {option_description=Mounted fused disconnect, notes=null, option_type=Electrical, models_used_on=1 Fan (230V), option_code=FSD.001-3} {option_description=Mounted fused disconnect, notes=null, option_type=Electrical, models_used_on=1 Fan (460V), option_code=FSD.001-4} {option_description=Mounted fused disconnect, notes=null, option_type=Electrical, models_used_on=2 Fan (230V), option_code=FSD.001-5} {option_description=Mounted fused disconnect, notes=Not suitable for 2 Fan Large (460V) Units (901M6 - 1001M6 1201L6 - 1301L6), option_type=Electrical, models_used_on=2 Fan (460V), option_code=FSD.001-6} {option_description=Mounted fused disconnect, notes=Not suitable for 2 Fan Large (460V) Units, option_type=Electrical, models_used_on=2 Fan (460V), option_code=FSD.001-6} {option_description=Mounted fused disconnect, notes=null, option_type=Electrical, models_used_on=2 Fan Large (230V), option_code=FSD.001-7} {option_description=Mounted fused disconnect, notes=null, option_type=Electrical, models_used_on=2 Fan Large (460V), option_code=FSD.001-8}
Electrical
Option Code Option Description List Price Adder (US$) Notes
SW.002 Dual pressure control with adjustable high & low pressure settings 166 Standard heated and insulated receiver kit option can't be used with this option. Contact factory
SW.007 Adjustable high pressure switch w/ manual reset & adjustable low pressure switch 424
DFT.001 Defrost Timer - Air 602 Medium temperature applications only.
FCY.014 Fan Cycling - Temperature & Pressure 594
PLM.001 Phase Loss Monitor 1,235
MS.001-5 Variable Speed EC Motor with Orbus Controller 4,016 Not suitable for 2 Fan Large (460V) Units (901M6 - 1001M6 1201L6 – 1301L6)
MS.001-5 Variable Speed EC Motor with Orbus Controller 4,016 Not suitable for 2 Fan Large (460V) Units
FSD.001-6 Mounted fused disconnect 4,016 Not suitable for 2 Fan Large (460V) Units (901M6 - 1001M6 1201L6 - 1301L6)
FSD.001-6 Mounted fused disconnect 4,016 Not suitable for 2 Fan Large (460V) Units
{option_description=Additional Heater Contactor and hold out relay, notes=48 amp maximum heater load per heater contactor. Can only have a maximum of 2 heater contactors per unit., option_type=null, models_used_on=All, option_code=DFT.CHR} {option_description=Electric Defrost Kit, notes=Includes (1) electric defrost timer (1) heater contactor (48 amp maximum heater load) (1) fan contactor terminal strip and fusing, option_type=null, models_used_on=All, option_code=DFT.KIT} {option_description=InterLink™ Smart Defrost Kit™, notes=Can not be used alone. Must also select a electric defrost timer or electric defrost kit., option_type=null, models_used_on=All, option_code=SDK.001}
$itemJson.get("option_type")
Option Code Option Description List Price Adder (US$) Notes
DFT.CHR Additional Heater Contactor and hold out relay 736 48 amp maximum heater load per heater contactor. Can only have a maximum of 2 heater contactors per unit.
DFT.KIT Electric Defrost Kit $number.format("integer", $optionsPricing.map.get($oj.get('option_code'))) Includes (1) electric defrost timer (1) heater contactor (48 amp maximum heater load) (1) fan contactor terminal strip and fusing
SDK.001 InterLink™ Smart Defrost Kit™ 930 Can not be used alone. Must also select a electric defrost timer or electric defrost kit.
{option_description=Replaceable core liquid-line filter drier & sight glass, notes=null, option_type=Mechanical, models_used_on=All, option_code=LIQ.003} {option_description=Compressor Unloading (One Step), notes=null, option_type=Mechanical, models_used_on=All, option_code=UNL.001} {option_description=Oil separator with discharge line check valve, notes=null, option_type=Mechanical, models_used_on=1 Fan, option_code=DIS.001-1} {option_description=Oil separator with discharge line check valve, notes=null, option_type=Mechanical, models_used_on=2 Fan, option_code=DIS.001-2} {option_description=Oil separator with discharge line check valve, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=DIS.001-3} {option_description=Head pressure control valve - 180psi fixed, notes=null, option_type=Mechanical, models_used_on=1 & 2 Fan, option_code=DIS.004-1} {option_description=Head pressure control valve - adjustable, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=DIS.004-2} {option_description=Liquid-line solenoid valve, notes=Not recommended on applications with line runs more than 25 feet., option_type=Mechanical, models_used_on=1 Fan, option_code=LIQ.002-1} {option_description=Liquid-line solenoid valve, notes=Not recommended on applications with line runs more than 25 feet., option_type=Mechanical, models_used_on=2 Fan, option_code=LIQ.002-2} {option_description=Liquid-line solenoid valve, notes=Not recommended on applications with line runs more than 25 feet., option_type=Mechanical, models_used_on=2 Fan Large, option_code=LIQ.002-3} {option_description=Heated & Insulated reciever with low pressure cut-out time delay, notes=null, option_type=Mechanical, models_used_on=1 & 2 Fan, option_code=LOW.001-1} {option_description=Heated & Insulated reciever with low pressure cut-out time delay, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=LOW.001-2} {option_description=Louvered guard for snowbelt regions, notes=null, option_type=Mechanical, models_used_on=1 Fan, option_code=LVR.001-1} {option_description=Louvered guard for snowbelt regions, notes=null, option_type=Mechanical, models_used_on=2 Fan, option_code=LVR.001-2} {option_description=Oversized receiver, notes=See technical bulletin for Volumes, option_type=Mechanical, models_used_on=2 Fan Large, option_code=REC.010-1} {option_description=Oversized receiver, notes=See technical bulletin for volumes, option_type=Mechanical, models_used_on=2 Fan, option_code=REC.010-2} {option_description=Oversized receiver, notes=See technical bulletin for volumes, option_type=Mechanical, models_used_on=1 Fan, option_code=REC.010-3} {option_description=Suction-line filter, notes=null, option_type=Mechanical, models_used_on=1 Fan, option_code=SUC.003-1} {option_description=Suction-line filter, notes=null, option_type=Mechanical, models_used_on=2 Fan, option_code=SUC.003-2} {option_description=Suction-line filter, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=SUC.003-3} {option_description=Replaceable core suction-line filter, notes=null, option_type=Mechanical, models_used_on=1 Fan, option_code=SUC.005-1} {option_description=Replaceable core suction-line filter, notes=null, option_type=Mechanical, models_used_on=2 Fan, option_code=SUC.005-2} {option_description=Replaceable core suction-line filter, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=SUC.005-3} {option_description=Suction accumulator, notes=null, option_type=Mechanical, models_used_on=1 Fan, option_code=SUC.007-1} {option_description=Suction accumulator, notes=null, option_type=Mechanical, models_used_on=2 Fan, option_code=SUC.007-2} {option_description=Suction accumulator, notes=null, option_type=Mechanical, models_used_on=2 Fan Large, option_code=SUC.007-3}
Mechanical
Option Code Option Description List Price Adder (US$) Notes
LIQ.003 Replaceable core liquid-line filter drier & sight glass 509
UNL.001 Compressor Unloading (One Step) 2,444
DIS.001-2 Oil separator with discharge line check valve 1,497
DIS.004-1 Head pressure control valve - 180psi fixed $number.format("integer", $optionsPricing.map.get($oj.get('option_code')))
LIQ.002-2 Liquid-line solenoid valve 748 Not recommended on applications with line runs more than 25 feet.
LOW.001-1 Heated & Insulated reciever with low pressure cut-out time delay 857
LVR.001-2 Louvered guard for snowbelt regions 1,477
REC.010-2 Oversized receiver 664 See technical bulletin for volumes
SUC.003-2 Suction-line filter 865
SUC.005-2 Replaceable core suction-line filter 1,336
SUC.007-2 Suction accumulator 1,218
{option_description=Bronz-Glow coil coating, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.BRZ-1} {option_description=Bronz-Glow coil coating, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.BRZ-2} {option_description=Bronz-Glow coil coating, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.BRZ-3} {option_description=Copper condenser fins, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.CPR-1} {option_description=Copper condenser fins, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.CPR-2} {option_description=Copper condenser fins, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.CPR-3} {option_description=BohnGuard™ condenser fin protection, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.PRO-1} {option_description=Polyester coated condenser fin protection, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.PRO-1} {option_description=ProKote™ condenser fin protection, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.PRO-1} {option_description=BohnGuard™ condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.PRO-2} {option_description=Polyester coated condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.PRO-2} {option_description=ProKote™ condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.PRO-2} {option_description=BohnGuard™ condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.PRO-3} {option_description=Polyester coated condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.PRO-3} {option_description=ProKote™ condenser fin protection, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.PRO-3} {option_description=ElectroFin coil coating, notes=null, option_type=Coil, models_used_on=1 Fan, option_code=CS.ELEC-1} {option_description=ElectroFin coil coating, notes=null, option_type=Coil, models_used_on=2 Fan, option_code=CS.ELEC-2} {option_description=ElectroFin coil coating, notes=null, option_type=Coil, models_used_on=2 Fan Large, option_code=CS.ELEC-3}
Coil
Option Code Option Description List Price Adder (US$) Notes
CS.BRZ-2 Bronz-Glow coil coating $number.format("integer", $optionsPricing.map.get($oj.get('option_code')))
CS.CPR-2 Copper condenser fins $number.format("integer", $optionsPricing.map.get($oj.get('option_code')))
CS.PRO-2 BohnGuard™ condenser fin protection 1,838
CS.PRO-2 Polyester coated condenser fin protection 1,838
CS.PRO-2 ProKote™ condenser fin protection 1,838
CS.ELEC-2 ElectroFin coil coating $number.format("integer", $optionsPricing.map.get($oj.get('option_code')))

Shipped Loose
Part Type Part Number Part Description List Price (US$)
mechanical options 50053301 8" Extended Legs 470
mechanical options 59898901 Hail Guards 566
Shipped Loose
Part Type Part Number Part Description List Price (US$)
2930142 328
29346101 450
29394306 2,522
29399012 662
4262Q 2,832

Product Add-ons

intelliGen™ Refrigeration Controller
intelliGen™ Refrigeration Controller

The intelliGen™ Refrigeration Controller is a factory-mounted electronic control that delivers reliable operation and system performance. intelliGen helps reduce food spoilage by maintaining better temperature control and provides energy savings through optimizing defrosts.

Learn more
Warranty
Warranty

Our refrigeration systems are built using durable materials and top-of-the-line components to fortify their longevity of use. Every product in our inventory is supported by the industry’s most trusted warranties, ensuring years of reliable performance and user satisfaction.

Learn more
Interlink Parts Lookup
Interlink Parts Lookup

InterLink Parts provides wholesalers and distributors with a comprehensive selection of product solutions and innovative technologies for the installed base, backed by a dedicated customer service team and the resources to deliver the best lead times in the industry.

Learn more
Feedback